Autodesk revit 2015 mep fundamentals pdf free download. What is Revit?

Looking for:

Autodesk revit 2015 mep fundamentals pdf free download -  













































     


Autodesk Revit MEP Fundamentals -



 

Avast Free Security. WhatsApp Messenger. Talking Tom Cat. Clash of Clans. Subway Surfers. TubeMate 3. Google Play. Windows Windows. Most Popular. New Releases. Desktop Enhancements. Learning to use Autodesk Revit will not make you a better architect.

However, it will allow you to communicate your ideas and designs faster, more easily, and more beautifully. For additional information on downloading, unzipping, and using these files visit the downloads section on our FAQ page.

B Annotating Views Open navigation menu. Close suggestions Search Search. User Settings. Skip carousel. Carousel Previous. Carousel Next. What is Scribd? Explore Ebooks.

Bestsellers Editors' Picks All Ebooks. Explore Audiobooks. Bestsellers Editors' Picks All audiobooks. Explore Magazines. Editors' Picks All magazines. Explore Podcasts All podcasts. Difficulty Beginner Intermediate Advanced. Explore Documents. Revit Structure. Uploaded by Fue Unp. Document Information click to expand document information Description: revit Did you find this document useful?

Is this content inappropriate? As there is no current selection, you need to select the elements to move. In Lab , select the two air terminals on the right and then press. Select a base point on one of the air terminals and then use temporary dimensions to move the air terminals 4'-0", as shown in Figure Task 2 - Array and mirror elements. Select the WC and lavatory. In the Options Bar, review the defaults. Pick the first point near one of the fixtures and a second point 3'-0" below using temporary dimensions.

You are prompted again for the number of elements, as shown in Figure Change the number to 4, and then press. The additional fixtures are placed, as shown in Figure They are 8. Click grouped together. Each element can now be moved separately. Click i, Modify and select the WCs. Select the wall between rooms and , as shown in Figure Select one of the lavatories, right-click and select Create Similar.

Place the lavatory across from the WC in the Women's room. Click Modify , select and drag the lavatory into place.

With the lavatory still selected, start the Array command. Click a base point on the lavatory, and then click a second point 3'-0" below it. Four lavatories are now placed, which do not need to be ungrouped. Select two of the WCs in Room Copy the lighting fixtures to the other rooms on the same side of the hall, similar to the example shown in Figure Add a Plain Recessed Lighting Fixture: 2x2 - type lighting fixture to the room with the 45 degree ceiling.

Remember to use Place on Face. Click Modify and select the new square lighting fixture. Drag the center control over to the edge, as shown in Figure Click when the cursor displays a horizontal line as shown in Figure and then on the nearby 45 degree angled line as shown in Figure X V Neatest Figure 8. The fixture now fits within the grid. Copy the fixture to additional places in the room. What is the purpose of an alignment line? Displays when the new element you are placing or drawing is aligned with the grid system.

Indicates that the new element you are placing or drawing is aligned with an existing object. Displays when the new element you are placing or drawing is aligned with a selected tracking point. Indicates that the new element is aligned with true north rather than project north. Which of the following commands imports a component such as the sink shown in Figure that is not available in your project?

Load Family b. Load Equipment c. Load Component d. How do you select all Lighting Fixture types, but no other elements in a view? In the Project Browser, select the Lighting Fixtures category. Select all of the objects in the view and use Filter to clear the other categories.

Select one Lighting fixture, and click Select Multiple in the Ribbon. Start the command first and then select the objects, or select the objects and then start the command. Start the command from the Modify tab, or select the object and then select Move or Copy from the right-click menu. Start the command from the Modify tab, or select the objects and select Auto-Move.

Where do you change the type for a selected plumbing fixture, as shown in Figure ? Select the dynamic control next to the selected plumbing fixture and select a new type in the drop-down list. In Properties, select a new type in the Type Selector drop-down list.

How do you move the center of rotation to another point as shown in Figure ? Select all that apply. Select the center of rotation and drag it to a new location.

In the Options Bar, click Place and select the new point. Center and d. As you connect components, you create systems which enable you to test the usefulness of these connections. Systems can be viewed in the Systems Browser. For electrical systems, wiring can also be generated, but these elements are only symbolic and annotative. In-depth steps for creating these connections are covered later in this training guide.

Figure How To: Connect Components 1. Select a component and click on the connector icon. In the Type Selector, select the type, as shown in Figure For example, you would select a pipe that matches the kind of system you are creating.

In the contextual tab, Options Bar, and Properties, specify the required options, as shown in Figure The options that are available depend on the type of elements you are working with. The process of combining these components and ensuring they work properly is a significant part of developing an HVAC project.

You also add hydronic piping connecting mechanical equipment. Mechanical equipment families are managed in Properties and have connectors, as shown in Figure In the Type Selector, select a mechanical equipment type.

In Properties, set any other values, such as the Level and Offset, if it is not hosted. In the Options Bar, specify if you want to be able to rotate the equipment after placement. Place the equipment in the model by clicking at the required location in the model view. You can place individual air terminals or batch copy them from a linked model.

Therefore when placing an air terminal, use a reflected ceiling plan view. How To: Place an Air Terminal y 1. In the Type Selector, select an air terminal type. Place on Work Plane Places the air terminal on a defined plane such as a level or ceiling in a linked architectural model.

In Properties, set the Flow and other parameters. Place the air terminal in the model by clicking at the desired location in the model view. Modify to exit the command. Some air terminal types prompt you to select sizes as shown in Figure This can be an advantage of using hosted fixtures.

This gives them control over the height of the families, if the architect moves the ceilings up or down, the engineer adjusts the height of the reference plane to match. If the architect deletes the ceiling and puts a new one in the linked model, the hosted air terminals are orphaned and do not move with changes in the ceiling height. A warning box opens when you reload the linked model or reopen the MEP project, as shown in Figure Use the Coordination Monitoring tools to address the issue.

It is not modified if the linked architectural model is modified. Have a duct in place. If it is a round or oval duct, verify the diameter before selecting the air terminal. Start the Air Terminal command. In the Type Selector, select the required air terminal. There are different types for curved and rectangular duct faces. Curved face air terminals are created by duct diameter as shown in Figure Ensure that you are selecting an air terminal that matches the system type of the duct.

Move the cursor over to the duct where you want to place the air terminal. The air terminal automatically rotates to the face you are closest to, as shown in Figure Figure 6. Click to place the air terminal. This works with independently placed air terminals and those placed directly on ducts, as shown in Figure Figure Rehosting Air Terminals While working with linked models, if air terminals are copied from one ceiling to other ceilings of the same height, the copied air terminals are hosted by their respective new ceilings.

However, if the ceilings are a different height than the ceiling that hosts the original air terminal, the copied fixtures are not associated with the ceiling. They end up at the same elevation as the original air terminal, as shown in Figure Therefore, you need to rehost the air terminal. If the ceilings are in the host project you are not permitted to copy a hosted air terminal from one ceiling to another.

Copy the air terminals as required. Select the one s that need to be rehosted to a different ceiling. Select the ceiling to which you want the air terminal s hosted. This results in faulty heating and cooling load calculations and incorrect space values.

To correct this, use a family that has the Room Calculation Point turned on. The point is displayed in the project when a fixture is selected, as shown in Figure However, the point cannot be manipulated and its visibility is only for review purposes.

Not all air terminals or light fixtures have this feature turned on by default. It must be added in the Family Parameters of the component. You will then place supply and return air terminals on the face of a ceiling. You will align the air terminals to the ceiling grid and copy the air terminals as required to create the layout shown in Figure There are some existing HVAC systems and open locations where you will add components, as shown in Figure Zoom in on the north wing, shown in Figure Place the AHU so that the connectors are facing the hallway, as shown in Figure While still in placement mode, press until the equipment is rotated degrees.

Place another AHU outside of the classroom doors on the opposite side of the hall, as shown in Figure Click Modify. Repeat this on the other side of the hall. Task 2 - Add air terminals. In this view you can see the locations of the ceiling grid and light fixtures provided in the architectural project.

Move the cursor into the project. As the cursor passes over a ceiling, the ceiling highlights. Place the air terminal near one of the lighting fixtures, as shown in Figure Type AL to start the Align command. Align the air terminal to the grid. Type CO to start the Copy command. Select the air terminal and press. Select the end point of one corner of the air terminal as the base point, and then place copies beside each of the other lighting fixtures in the same room and the room beside it, as shown in Figure Select one of the air terminals.

In Properties, note that Elevation is grayed out because the air terminal is attached to the face of the ceiling, which is at 9'-0".

Zoom out so that one of the existing systems in the same hallway displays. Select one of the return diffusers, right-click and select Create Similar. The Air Terminal command is started with the correct type and properties automatically applied. Place two return diffusers in the rooms, as shown in Figure Angle Use in Layout The process of adding various types of duct or pipe is essentially the same whether you are drawing standard, flex, or placeholder elements.

There are several ways to start the commands: 1. Select the element, hover the cursor over a connector icon, and then select the command, as shown in Figure Select the element, right-click on a connector, and then select the command name, as shown in Figure Start the command using one of the options outlined above.

In the Type Selector, select a type as shown for ducts in Figure You can limit the number of options that display by typing part of the name in the search box. If you are drawing ducts or pipes without selecting an existing connector, in Properties, specify the System Type as shown in Figure before you start drawing the elements.

Drawing from existing connectors automatically applies the System Type. Figure 4. If you started from a connector, the default sizes and offset match the parameters of the selected connector. Set up the various placement options, as outlined in the next section. Draw the elements using temporary dimensions, snaps, and alignments to locate each point along the path as shown in Figure So that started with us going exclusively Revit.

Joseph Cory, Architect, Geotectura Studio. Watch video: min. BIM helped us keep ahead of the fast-paced project. Read story. Company overview US Site. Careers US Site. Investor relations US Site. Newsroom US Site.

   


Comments